ClimateMaster DC Series Installation Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 50
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
3
Residential H&V - 60Hz R22 &R410A
Rev.: 22 Dec, 2008
climatemaster.com
CAUTION: Indicates a potentially hazardous situation or an
unsafe practice, which if not avoided could result in minor or
moderate injury or product or property damage.
NOTICE: Noti cation of installation, operation or
maintenance information, which is important, but which is
not hazard-related.
Model Nomenclature: General Overview For All H & V Series
NOTE: Above model nomenclature is a general reference. Consult individual speci cation sections for detailed information.
WARNING! Verify refrigerant type before proceeding. Units
are shipped with R-22, R-407c and R-410A (EarthPure
®
)
refrigerants. The unit label will indicate which refrigerant is
provided. The EarthPure
®
Application and Service Manual
should be read and understood before attempting to
service refrigerant circuits with R-407c or R-410A.
WARNING! To avoid the release of refrigerant into the
atmosphere, the refrigerant circuit of this unit must be
serviced only by technicians who meet local, state, and
federal pro ciency requirements.
WARNING! All refrigerant discharged from this unit must
be recovered WITHOUT EXCEPTION. Technicians must
follow industry accepted guidelines and all local, state,
and federal statutes for the recovery and disposal of
refrigerants. If a compressor is removed from this unit,
refrigerant circuit oil will remain in the compressor. To
avoid leakage of compressor oil, refrigerant lines of the
compressor must be sealed after it is removed.
CAUTION!
To avoid equipment damage, DO NOT use
these units as a source of heating or cooling during the
construction process. The mechanical components and
lters will quickly become clogged with construction dirt
and debris, which may cause system damage.
A0 1 8 CG 0 0 C L T
4 5 6 7
8
91011121314
UNIT SIZE, MBtuh:
RETURN AIR:
VOLTAGE:
C = CXM
CONTROLS:
REVISION LEVEL:
HEAT EXCHANGER OPTIONS:
CABINET:
SUPPLY AIR FLOW & MOTOR OPTION:
TS
1 2
TT = Tranquility
27
TM
Two-Stage -
EarthPure
®
(R-410A)
TS = Tranquility
20
TM
Single-Stage
EarthPure
®
(R-410A)
GS = Genesis Series - R22
SERIES:
V
3
V = VERTICAL UPFLOW
CONFIGURATION:
L = LEFT RETURN
R = RIGHT RETURN
0 = NONE
HOT WATER GENERATOR OPTIONS:
S
15
S = STANDARD
STANDARD:
H = HORIZONTAL
D = VERTICAL DOWNFLOW
(D N/A for GS Series - See Digit 14)
0 = RESIDENTIAL CLASS
1 = HWG W/INTERNAL PUMP
OPTION SUPPLY CONFIGURATION MOTOR
T
D
B
TOP
DOWN
BACK
TSV/GSV
TSD/GSV
TSH/GSH
PSC*
PSC*
PSC*
S STRAIGHT TSH/GSH PSC*
K TSV ECM
N TSD ECM
P TSH ECM
W TSH ECM
TOP
DOWN
BACK
STRAIGHT
* PSC MOTOR N/A FOR TT SERIES
THIS SELECTION IS FOR BOTH PSC & ECM FOR GS SERIES
Rev.: 04/21/08B
NOTE: Some options/configurations not available on all series. Please consult Specification Catalogs for model specific options.
E = CXM w/ECM Fan (GS only)
G = 208-230/60/1
Standard
Coated Air Coil
Copper Cupro-Nickel
AJ
ClimaDry
DN/A
Notes
+
= Only Available With ClimaDry Option
*
= Not Available On DownFlow Units
*
D = DXM
+
WARNING!
WARNING!
WARNING!
CAUTION!
Safety
Warnings, cautions and notices appear throughout this
manual. Read these items carefully before attempting any
installation, service or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation, which
if not avoided will result in death or serious injury. DANGER
labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation, which
if not avoided could result in death or serious injury.
Section 10 - Packaged IOM 3 4/24/09 3:16:48 PM